Daikin Floor Standing AC FVPGR18NY1 (18.0Hp) - 3 Phase

Daikin Floor Standing AC FVPGR18NY1 (18.0Hp) - 3 Phase

150,800,000
Phí vật tư có thể phát sinh: 5,006,000đ. Xem chi tiết vật tư.

Email: kinhdoanh@sieuthimaylanh.com
(Open 08. am-17.pm everyday)
Warranty
02 years for components
05 years for compressor
Capacity
Air Conditioner 18.0 HP
Type
Non-Inverter Air Conditioner
Refrigerant
Gas R410A
Specifications
Made in:Brand of Japanese, Made in Thailand
Refrigerant:R410A
Type:Non - Inverter AC - Cooling Only
Cooling Capacity:18.0 Hp - 180.000 Btu/h
Use For Room:Room Area 235 - 240 m² or Volume 705 - 720 m³ ( Suitable for living room, office )
Power Input (Ph/V/Hz):3 Phase, 380 - 415 V, 50Hz
Power consumption (kW):21,2 Kw
Refrigerant/ Liquid Pipe Diameter (mm):15.9 / 34.9
Maximum Pipe Length:50 (m)
Maximum Elevation Length:30 (m)
Indoor Unit
Indoor Unit Model:FVPGR18NY1
Indoor Unit Dimensions (mm):1.870 x 1.470 x 720 (mm)
Indoor Unit Net Weight (Kg):240 (kg)
Outdoor Unit
Outdoor Unit Model:RUR18NY1
Outdoor Unit Dimensions (mm):1.680 x 1.240 x 765 (mm)
Outdoor Unit Net Weight (Kg):322 (kg)
Description

Packaged Air Conditioners

Success at research facilities and factories often hinges on strict control of air temperature and quality. To these environments, Daikin offers an abundant range of packaged air conditioners for precise control of air and temperature to help preserve accurate results and product quality.

Daikin Advantages

Energy Saving

Using advanced inverter and heat pump technologies increases efficiency and reduces energy consumption.

 Wide Range of Solutions

Daikin provides a wide range of applications that require high precision in temperature control and air quality.

Control by Zone / Area

Daikin packaged air conditioners combine with ducts to distribute air only to zones and areas where needed.

Durability

Heat exchange fins provided with anti-corrosion treatment (Applies to all outdoor units)
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit

Design flexibility

Designed for long refrigerant piping. 50 m maximum length and 30 m maximum level difference to cover medium- and large-scale building needs.

daikin_FVGR05NV1

4-direction piping affords more freedom

Piping can be run from the front, bottom, right or rear surface according to how the unit is installed.
In case of RUR08–20N, piping can be drawn out in two directions-front, and under side.of layout (Applies to RUR05N/06N)

Floor Standing Duct Connection Type

  • Comfortable air conditioning of the entire factory by connecting a blow duct at the top of the indoor unit
  • Installation is next to walls, so units will not affect the factory layout even if the changes are made
  • Flexible desaign for long refrigerant piping
  • Equipped with scroll compressor for quiet operation
  • Easy operation digital remote control comes standard with indoor unit
  • Heat exchange fins provided with anti-corrosion treatment
  • Installation space is saved thanks to a more compact outdoor unit. This also makes it easier to install.
  10 HP 13HP 15HP 18HP 20HP
 Model   Name Indoor Unit FVPGR10NY1 FVPGR13NY1 FVPGR15NY1 FVPGR18NY1 FVPGR20NY1
 Outdoor Unit RUR10NY1 RUR13NY1 RUR15NY1 RUR18NY1 RUR20NY1
 Cooling Capacity*1.3 kW 29,3 35,2 46,9 52,8 58,6
 Btu/h 100.000 120.000 160.000 180.000 200.000
 Power Consumption*1 kW 11,4 14,9 17,8 21,2 24,8
 Indoor Unit Sound Level (H/L)*2 dB(A) 61 62 62 63 63
 Dimensions (H x W x D) Unit mm 1740 x 170 x 510 1870 x 1170 x 720 1870 x 1470 x 720
 Outdoor   Unit Sound Level (H/L)*2 380V dB(A) 61 61 62 63 63
 415V 62 62 63 64 64
 Dimensions (H x W x D) Unit mm 1680 x 930 x 765 1680 x 1240 x 765
 Refrigerant   Piping Indoor Unit Liquid  mm Ø12,7 (brazing) Ø15,9 (brazing)
 Gas  mm Ø28,6 (brazing) Ø34,9 (brazing)
 Drain mm PS 1B Internal Thread
 outdoor Unit Liquid  mm Ø12,7 (flare) Ø15,9 (flare)
 Gas  mm Ø28,6 (brazing) Ø34,9 (brazing)
 Drain mm--------------------------------
 Max. Interunit piping lenght m 50 (equivalent length 70)
 Max. Installation level difference m 30

 

Note:
*1Rated cooling capacities are based on the following conditions: Return air temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
*2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
*3Capacity includes indoor fan motor heat.

0