Draft Prevention Panel
Draft Prevention Panel prevents cold / hot draft being blown directly on the user.
It is possible to set Draft Prevention Panel for each air outlet.
User can position Draft Prevention Panel panels by using the remote controller only (RC-EX3, RCN-T-5AW-E2).
Advanced airflow control technology cultivated through aircraft development.
Motion Sensor
Motion sensor is equipped in the panel corner and detects the presence/absence and activity of humans in a room to improve the comfort and energy saving performance of the unit.
Improve the aerodynamic performance of the unit
New designed component can have better aerodynamic perfromance and achieve lower noise.
Panel select pattern
8 patterns of panel are avilable.
① Standard Panel only
①+③ Standard Panel with corner panel with motion sensor
①+④ Standard Panel with corner panel with wireless receiver
①+⑤ Standard Panel with corner panel with motion sensor & corner panel with wireless receiver
② Draft Prevention Panel only
②+③ Draft Prevention Panel with corner panel with motion sensor
②+④ Draft Prevention Panel with corner panel with wireless receiver
②+⑤ Draft Prevention Panel with corner panel with motion sensor & corner panel with wireless receiver
Installation position of Wireless kit and Motion sensor kit.
Individual flap control system
According to room conditions, four directions of air flow can be controlled individually by utilizing the flap control system. Individual flap control is available even after installation.
Flap can swing within an upper and lower flap range position within can be selected with a wired remote control.
*The wireless remote control is not applicable to the Individual flap control system.
850mm Drain Pump
Drain can be discharged upwards by 850mm from the ceiling surface. It allows a piping layout with a high degree of freedom. Depending on the installation location and 185mm flexible hose as a standard equipment supports easy workability.
Easy check of drain pan
Easy check of drain pan condition is available by removing corner lid only.
Remote control (option)
Specifications
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*Powerful-Hi can be selected. Sound pressure level: FDT28/36 37dB(A), FDT45/56 38dB(A), FDT71 47dB(A), FDT90/112/140/160 49dB(A). Air flow: FDT28 15m3/min, FDT36 16m3/min, FDT45 17m3/min, FDT56 20m3/min, FDT71 28m3/min, FDT90 37m3/min,, FDT112/140/160 38m3/min.