Specifications
Made in Brand of Japanese, Made in Thailand
Refrigerant R410A
Type Inverter AC - Cooling Only
Cooling Capacity 2.5 Hp - 20.500 Btu/h
Use For Room Room Area 31 - 35 m² or Volume 93 - 105 m³ ( Suitable for living room, office )
Power Input (Ph/V/Hz) 1 phase, 220 - 240V, 50Hz
Power consumption (kW) 6,0 Kw
Refrigerant/ Liquid Pipe Diameter (mm) 6.35 / 12.7
Indoor Unit
Indoor Unit Dimensions (mm) 248 x 570 x 570 (mm)
Indoor Unit Net Weight (Kg) 15 (kg)
Panel
Panel Dimensions (mm) 35 x 700 x 700 (mm)
Panel Net Weight (Kg) 3.5 (kg)
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Product Description

SCM Multi Premium - SRK - ZR Wall mounted type
CERTIFIED BY RoHS Standard

Adapted to RoHS directvive

RoHS: Restriction of Hazardous substances

In order to avoid the release of hazardous substances into the environments, all models have utilized lead-free solder application. It has been considered to be difficult to use lead-free solder for practical applications because it requires higher solder temperatures as assembly, which can jeopardize reliability. However our PbF soldering method can produce a higher quality lead-free printed circuit board.

QUICK & HIGH FEFICIENCY CONTROL DC INVERTER

An inverter driven systam has a number of perfomance advantages over a constant speef system. For example, its variable compressor output can ensure quick heating afer a startup and attain a set temperature more quickly.
Then, The air conditioner can slow down its compressor speed to save energy, keeping comfortable conditions. Moreover, the compressor is DC driven, so it provides higher performance.

New Inverter Control ( Vector control)

The new inverter control, with the advanced vector control technology, functions at high efficiency.
Smooth operation from low speed to high speed
Smooth Sine Voltage Wave fform ả
Energy efficiency is furrther improved in low speed range.

Employment of R410A

All models use refrigerant R410A characterized by the ozone depletion coefficient being 0.

Remote control

COMFORTABLE FUNTIONS

Fuzzy auto mode
Automatically, the unit determines its operating mode and adjusts the inverter frequency..
Automatic Operation
The air conditioner automatically selects from among heating, cooling and dry operations.

COMFORTABLE AIR FLOW FUNCTIONS

Auto flap mode
Whatever the operating mode is the unit automatically selects the optimal angle.
Memory flap
While the flap is swinging it can be stopped at any angle desired. The flap returns to  the position that it was in when operation last stopped.
Up/Down flap swing
The UP/DOWN flap can be adjust to the preferred operations angle, ranging from horizontal to perpendicular.

Maintenance & Prevention Funtions

Microcomputer- Operated Defrosting
This mode automatically eliminates frost and helps minimize excessive operation in other modes.
Self-Diagnostic Funtion
In the case that the air conditioner malfunctions an internal microcomuter automatically runs a self-diagnosis.

CONVENIENCE & ECONOMY FUNCTIONS

Dry operation
The unit dehumidifies the room by intermittent cooling operation.
Sleep Mode
The room temperature is automatically controlled during the set sleep mode period, ensuring that room temperature will not get too cold or too hot
Off Timer
The unit stops automatically at the set time.
On Timer
This facility enables the operation to start a littel earlier, so that the room approaches optimum temperaure at ON time when the operation is started by ON-TIMER.
Thus it will try to e at the temperature you want.
24-hour On/Off programmanle timer
by combining a start timer with a stop timer, you can register two timer operationsa day. Once set, timers will faithfully start or stop the system at a specified time of the day repeatedly.

OTHERS

Back-up Switch
On the main unit, there is a backup on/off switch, which is useful when you can't use remote control or batteries are
Auto Restart Funtion
Power blackout auto restart function is a function that records, the operational status of the air-conditioner immediately prior to it being switched off by a power cut and the automatically resumes operations at that point after the power has been restored.

ITEM Model
FDTC25VF FDTC35VF FDTC50VF FDTC60VF
Nominal cooling capacity kW 2.5 3.5 5.0 6.0
Nominal heating capacity kW 3.4 4.5 5.8 6.8
Sound power level cooling dB(A) 56 58 60 60
Heating dB(A) 56 58 60 60
Exterior dimensions
(H x W x D)
indoor mm 248x570x570
panel mm 35x700x700
Netweight indoor kg 15
panel kg 3.5
Ref.piping size Liquid/gas mm 6.35(1/4'')/ 9.52(3/8'') 6.35(1/4'')/12.7(1/2'')