Cooling | Heating | |
5MKS100LSG | 3.69 | - |
5MXS100LVMA | 3.65 | 4.58 |
With the combination of:
We have created:
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory
2MKS40: 43 dB (A)
2MXS50: 45 dB (A)
Long piping length for installation flexibility
The ample maximum piping length of 80 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space
Model Name | Cooling only | 2MKS40 | 3MKS50 | 3MKS71 | 4MKS80 | 5MKS100 |
---|---|---|---|---|---|---|
Heat pump | - | 3MXS52 | 3MXS68 | 4MXS80 | 5MXS100 | |
Max. Piping length | Total | 30 m | 50 m | 60 m | 70 m | 80 m |
For 1 room | 20 m | 25 m | 30 m |
Wide Variety of Indoor Unit
Stylish indoor units for elegant interiors
Smart control
Connectable at up to 200% of the outdoor unit capacity class
If all indoor units will not be operated simultaneously, for example, during daytime use of the living room unit or nighttime use of the three bedroom units, the sum of the capacity classes of all indoor units that can be connected is up to 200% of the outdoor unit capacity class
Notes:
1. When an indoor unit is turned on, if the sum of the capacity classes of all indoor units exceeds the limit for simultaneous operation, the unit waits on standby.
2. Even an indoor unit that was initially set as prioritised under Priority-Room Setting waits on standby under the above condition 1.
3. When an indoor unit is turned off, the sum of the capacity classes of all indoor units is within the limit for simultaneous operation, the unit waiting on standby starts automatically.
2MKS40FV1B | 3MKS50ESG | 3MKS71ESG | 4MKS80ESG | 5MKS100LSG | ||
Outdoor unit capacity class (kW) | 4.0 | 5.0 | 7.1 | 8.0 | 10.0 | |
Limit of the sum of capacity classes of all indoor units | Connectable at 200% (kW) | — | — | 14.2 | 16.0 | 20.0 |
Simultaneous operation (kW) | 6.0 | 9.5 | 13.5 | 15.6 | 15.6 |
* Indoor units can be connected at up to 200% of outdoor units capacity class. All indoor units cannot be operated simultaneously
Indoor Unit
Slim and compact design
Models in the FDKS-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings.
Quiet operation
Quiet operation sound level of only 29 dB (A) is achieved for 2.5 and 3.5 kW class models during
Indoor Unit Quiet Operation.
Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.
* Home Leave Operation can be selected for any temperature from 18 to 32˚C for cooling operation and 10 to 30˚C for heating operation.
* Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home.
Note:
* The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for FDKS-EA and 40 Pa
for FDKS-C. Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for FDKS-C.