Reduce electricity bill
Daikin's new Inverter technology models reduce energy consumption during the cooling process.
Flexible installation
With a height of only 245 mm, installation is possible even in buildings with narrow ceilings.
Standard drain pump
The discharge pipe height is increased by 850 mm thanks to the use of the pre-installed DC drain pump with standard accessories.
Antibacterial to prevent odor
The antibacterial method is integrated in the indoor unit, using silver ions in the drain to prevent the growth of slime, bacteria, mold causing odors and blockages (the life of the silver ion tube depends on into the use environment, but should be replaced every 2 to 3 years).
Reluctance DC helical compressor
Daikin's DC inverter product line is equipped with a reluctance DC helical compressor.
Reluctance DC helical compressors use 2 different types of torque: Neodym magnet*1 and reluctance torque*2.
This motor saves energy because during operation it requires less power but still produces more power than traditional AC and DC motors.
Refrigerant cooling
Daikin's exclusive refrigerant cooling system delivers high cooling performance even at high outdoor temperatures.
High condensing capacity with micro channel heat exchanger
Larger heat exchanger area increases machine efficiency.
V-knotted propeller propeller
The use of a V-shaped propeller blade simulates the performance of a swan's wing, which ensures even and lossless air flow.
External static pressure adjustable
Using a DC fan motor the external static pressure can be adjusted between 50 Pa and 150 Pa.
Pleasant airflow is achieved depending on conditions such as duct length.
Simultaneous air conditioning for two rooms and ventilation (open ventilation)
When the air conditioners in two rooms are turned on at the same time, the amount of air supplied to each room must be recirculated back to the air conditioner. To ensure this, a ventilation system must be installed for each room or a ventilation door must be installed in a compartment on the wall or under the door between two rooms.
Function of automatic adjustment of air flow
Control the air flow by remote control during the test run.
Air volume is adjusted automatically to approximately +/- 10% high wind speed.
Control by interlock
As an energy-saving feature, the air conditioner can be interlocked with the hotel's magnetic door system. With the use of a third building management system, lighting and air conditioning can be controlled with an interlock mechanism.
Connection standard DIII-NET
Easy communication and connection to the central control system.
Suction line available at the bottom of the device
Easy maintenance
Location of the opening of the drain trough
Adjusted for easier inspection.
Drainage trough maintenance inspection window
This window makes it possible to check for dirt clinging to the drain pan and identify drainage during installation without the use of tools.
Remote controll
Specifications
Note:
1 Rated cooling capacity is based on the following conditions: Room temperature 27°CDB, 19° CWB; outdoor temperature 35° CDB, 24° CWB; refrigerant conduit equivalent to 7.5 m (horizontally)
2 Power is the actual value, deducting heat from the indoor unit motor.
3 External static pressure can be changed in 11 degrees by remote control.
4 Conversion value in anechoic room conditions. If measured under actual installation conditions, the actual value is often higher than the specification due to environmental noise and echo.
5 The air filter is not a standard accessory, but it is recommended to attach it to the ductwork on the intake side. Select dust filtration efficiency (gravity method) 50% or more.