Inverter

Dakin Ceiling Duct AC FBA71BVMA (3.0 Hp) Inverter

Listed price 41.342.000
Price35.300.000
( VAT included )
Saving 6.042.000
  • The selling price includes VAT and is committed to a genuine 100 percent NEW-WARRANTY NATIONWIDE.
  • Free delivery within Ho Chi Minh City-fast installation, overtime installation as required. Support delivery and installation in the province.
Specifications
Made in Brand of Japanese - Made in Thailand
Refrigerant R32
Type Inverter AC - Cooling Only
Cooling Capacity 3.0 Hp - 24.200 Btu/h
Use For Room Room area 36 - 40 m² or volume 108 - 120 m³
Power Input (Ph/V/Hz) 1 Phase, 220 - 240 V, 50Hz
Power consumption (kW) 2.15 kW
Refrigerant/ Liquid Pipe Diameter (mm) 9.52 / 15.88
Maximum Pipe Length 50 m
Maximum Elevation Length 30 m
Indoor Unit
Indoor Unit Model FBA71BVMA
Indoor Unit Dimensions (mm) 245 x 1000 x 800 (mm)
Indoor Unit Net Weight (Kg) 37 (Kg)
Outdoor Unit
Outdoor Unit Model RZF71CV2V
Outdoor Unit Dimensions (mm) 595 x 845 x 300 (mm)
Outdoor Unit Net Weight (Kg) 41 (Kg)
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Product Description

Reduce electricity bill

Daikin's new Inverter technology models reduce energy consumption during the cooling process.

Flexible installation

With a height of only 245 mm, installation is possible even in buildings with narrow ceilings.

Standard drain pump

The discharge pipe height is increased by 850 mm thanks to the use of the pre-installed DC drain pump with standard accessories.

Antibacterial to prevent odor

The antibacterial method is integrated in the indoor unit, using silver ions in the drain to prevent the growth of slime, bacteria, mold causing odors and blockages (the life of the silver ion tube depends on into the use environment, but should be replaced every 2 to 3 years).

Reluctance DC helical compressor

Daikin's DC inverter product line is equipped with a reluctance DC helical compressor.

Reluctance DC helical compressors use 2 different types of torque: Neodym magnet*1 and reluctance torque*2.

This motor saves energy because during operation it requires less power but still produces more power than traditional AC and DC motors.

Refrigerant cooling

Daikin's exclusive refrigerant cooling system delivers high cooling performance even at high outdoor temperatures.

High condensing capacity with micro channel heat exchanger

Larger heat exchanger area increases machine efficiency.

V-knotted propeller propeller

The use of a V-shaped propeller blade simulates the performance of a swan's wing, which ensures even and lossless air flow.

External static pressure adjustable

Using a DC fan motor the external static pressure can be adjusted between 50 Pa and 150 Pa.

Pleasant airflow is achieved depending on conditions such as duct length.

Simultaneous air conditioning for two rooms and ventilation (open ventilation)

When the air conditioners in two rooms are turned on at the same time, the amount of air supplied to each room must be recirculated back to the air conditioner. To ensure this, a ventilation system must be installed for each room or a ventilation door must be installed in a compartment on the wall or under the door between two rooms.

Function of automatic adjustment of air flow

Control the air flow by remote control during the test run.

Air volume is adjusted automatically to approximately +/- 10% high wind speed.

Control by interlock

As an energy-saving feature, the air conditioner can be interlocked with the hotel's magnetic door system. With the use of a third building management system, lighting and air conditioning can be controlled with an interlock mechanism.

Connection standard DIII-NET

Easy communication and connection to the central control system.

Suction line available at the bottom of the device

Easy maintenance

Location of the opening of the drain trough

Adjusted for easier inspection.

Drainage trough maintenance inspection window

This window makes it possible to check for dirt clinging to the drain pan and identify drainage during installation without the use of tools.

Remote controll

Specifications

Note:

1 Rated cooling capacity is based on the following conditions: Room temperature 27°CDB, 19° CWB; outdoor temperature 35° CDB, 24° CWB; refrigerant conduit equivalent to 7.5 m (horizontally)

2 Power is the actual value, deducting heat from the indoor unit motor.

3 External static pressure can be changed in 11 degrees by remote control.

4 Conversion value in anechoic room conditions. If measured under actual installation conditions, the actual value is often higher than the specification due to environmental noise and echo.

5 The air filter is not a standard accessory, but it is recommended to attach it to the ductwork on the intake side. Select dust filtration efficiency (gravity method) 50% or more.