*2. 9 o'clock is the default setting. Set up 8, 9, or 10 hours.
*3. In the case of a 10HP outdoor unit.
4-sided heat exchange ensures a large heat exchange area. So improves heat exchange efficiency without increasing size.
The electrical components have been shrunk and placed in the dead space of the air intake to reduce interference with airflow.
The electronic components are located at a reasonable top to help shorten the machine maintenance process. Besides, the front heat exchanger can be used efficiently to increase its efficiency.
RXQ46AMYM (W) is designed with an electrical box positioned above between low and high-pressure areas. This architecture allows the greatest airflow from low pressure to high pressure due to a higher pressure differential.
Without affecting the fan's air flow, the redesigned upper electrical components take advantage of dead space. So eliminates the suction.
It is possible to keep the operation stable even at high ambient temperature by cooling the inverter power module. So helps to maintain the air-conditioning capability and reduce the failure rate.
It is possible to keep the operation stable even at high ambient temperature by cooling the inverter power module. So helps to maintain the air-conditioning capability and reduce the failure rate.
Advantages of ODM:
Thanks to the large rotor diameter,
The long pipeline length makes the design more flexible, suitable for large buildings.
When connecting with VRV indoor unit only
When connecting a mixture of VRV indoor units and residential indoor units
connection capacity up to 130%.
RXQ46AMYM (W) achieves high external static pressure up to 78.4 Pa, ensures efficient heat dissipation, and keeps the unit running stably in a decentralized or centralized layout.
RXQ46AMYM (W) complex combines an efficient and simple operation of inspection, not only speeding up the installation process but also improving the quality of the installation on site.
RXQ46AMYM (W) uses 7-segment LEDs to display system operating information, enables the display of operating status, facilitates operation and implementation of the following services.
SMT technology applied to the entire computer control board improves anti-interference properties.
Protect your computer's control board against the effects of sand and wet weather.
Power consumption limits are set correctly with 11 levels. Power reduction should be carried out on a case-by-case basis.
* Install on the board of the outdoor unit.
The wide operating range of RXQ46AMYM (W)helps to limit installation location restrictions. The operating temperature range for cooling can realize when the outdoor temperature goes up to 49 ° C. Allows operation even under high-temperature conditions.
When starting up, RXQ46AMYM (W) will automatically activate the alternating operation mode to ensure balanced uptime of each outdoor unit to increase equipment life and operate smoothly.
RXQ46AMYM (W) is enhanced with dual redundant operations, ensuring maximum air conditioning in this area by emergency activation of operating functions backup even when something goes wrong in an air conditioning system. In the case of a failure, the emergency operating mode triggered, allowing the remaining device to run beyond a limit.
Backup machine operation feature: If one of the systems in the integrated outdoor unit configuration fails, the remaining outdoor systems will perform an emergency before the fix accomplish.
Features for backup compressor operation: The outdoor units equipped with two compressors. Even if one compressor malfunctions, another will operate in an emergency, reducing the risk of shutdowns due to compressor failure. (Capacity will keep during standby operation)
Các thành phần điện tử nằm ở vị trí hợp lý phía trên giúp rút ngắn quá trình bảo trì máy. Hơn nữa, bộ trao đổi nhiệt ở phía trước có thể được sử dụng hiệu quả để cải thiện hiệu suất của nó.
Outer shell
Multiple coatings for extreme durability: Use hot-dip galvanized - aluminum - magnesium steel sheet to resist strong corrosion, with a 4-layer coating for greater durability.
Corrosion resistance verified by reactive reaction test: Although the previous anti-corrosion model rusted, the outer shell of the RXQ46AMYM (W) outdoor unit complex showed no signs of corrosion in either experiment.
The heat exchanger (Wing)
Anti-corrosion technology: aluminum wings of RXQ46AMYM (W) developed with a thicker anti-corrosion coating include two additional layers.
High-performance technology:
Only the outer cover and wings are 3rd party certified for durability.
Corrosion resistance test obtained UL Certificate (Passed high resistance to corrosion grade C5 defined in ISO 12944-6: 2018.)
The new model resists salt corrosion, maintains performance, and reduces life cycle costs significantly.