One of the industry’s most compact bodies in the mid-static pressure range.
Higher lift is realized by utilising built-in DC drain pump with standard accessory
Bottom suction is available Wiring and servicing can be done from the underside of the unit (an option part required).
Comfort
Switchable fan speed:High/Middle/Low and Auto (“Auto” is applicable when BRC1E62 is used.)
Clean
Silver ion anti-bacterial drain pan A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause smells and clogging.
Using a DC fan motor, the external static pressure can be controlled to within a range of 50 Pa to 150 P
Airflow rate auto adjustment function Controls the airflow rate using a remote controller during test run. It is automatically adjusted to approximately ±10% of the rated H tap airflow.
Comfort airflow is achieved in accordance with conditions such as duct lengthComfort airflow is achieved in accordance with conditions such as duct length
Interlock control As an energy saving feature, the room air conditioning unit can be interlocked with the hotel key card system. Using a 3rd-party building management system, air conditioning and lighting can be interlocked. * Field setting with remote controller
DIII-NET communication standard Easier communication and connection with the centralised control system.
Easy maintenance
Position of drain pan inspection opening has been modified for easier inspection work
Drain pan maintenance check window This makes it possible to inspect for drain pan dirt and to confirm drainage during installation without the use of tools.
Easy maintenance because the drain pan can be removed
High efficiency
DC fan motor and DC drain pump are utilised to improve energy efficiency
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Note: The under-door cutout method should be used only when there is a small volume of airflow.
Note : 1. Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 2. Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3. Capacities are net, including a deduction for cooling for indoor fan motor heat. 4. External static pressure is changeable in 11 stages by remote controller. 5. The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 6. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.