Mitsubishi Heavy Ceiling Cassette FDT71CR-S5 (3.0Hp)
Mitsubishi Heavy Ceiling Cassette FDT71CR-S5 (3.0Hp)
Mitsubishi Heavy Ceiling Cassette FDT71CR-S5 (3.0Hp)

Mitsubishi Heavy Ceiling Cassette FDT71CR-S5 (3.0Hp)

28,900,000
3 công suất làm lạnh. Bạn đang chọn 3.0 Hp
Phí vật tư có thể phát sinh: 1,165,000đ. Xem chi tiết vật tư.

Email: kinhdoanh@sieuthimaylanh.com
(Open 08. am-17.pm everyday)
Warranty
02 year
Capacity
Air Conditioner 3.0 HP
Type
Non-Inverter Air Conditioner
Refrigerant
Gas R410A
Specifications
Made in:Brand of Japanese, Made in Thailand
Refrigerant:R410A
Type:Non - Inverter AC - Cooling Only
Cooling Capacity:3.0 Hp - 24.225 Btu/h
Use For Room:Room Area 36 - 40 m² or Volume 108 - 120 m³ ( Suitable for living room, office )
Power Input (Ph/V/Hz):1 phase, 220 - 240V, 50Hz
Power consumption (kW):2,29 Kw
Refrigerant/ Liquid Pipe Diameter (mm):6.35 / 15.88
Maximum Pipe Length:30 (m)
Maximum Elevation Length:10 (m)
Indoor Unit
Indoor Unit Model:FDT71CR-S5
Indoor Unit Dimensions (mm):246 x 840 x 840 (mm)
Indoor Unit Net Weight (Kg):24 (kg)
Panel
Panel Dimensions (mm):35 x 950 x 950 (mm)
Panel Net Weight (Kg):5.5 (kg)
Outdoor Unit
Outdoor Unit Model:FDC71RC-S5
Outdoor Unit Dimensions (mm): 640 x 850 x 290 (mm)
Outdoor Unit Net Weight (Kg):47 (kg)
Description

CEILING CASSETTE NON INVERTER FDT - 4 WAY 

Arrangement of installation

Checking from access ports with detachable covers at each corner, arrangement of installation balancer of indoor unit can be available without removing a panel.
Warkability is improved and time of installation is reduced.

Mitsubishi_Heavy_FDT50CR-S5_4

Easy checking of drain pan

Easy checking of drain pan condition is available by removing corrner lid only.
Due to new design changing fan motor is available without removing a panel.

Mitsubishi_Heavy_FDT50CR-S5_3

700MM DRAINPUMP

Drain can be disscharged upwardsby 700mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location and 260mm flexible hose as a standard equipment supports easy workability.
Mitsubishi_Heavy_FDT50CR-S5_2

REMOTE CONTROL

Mitsubishi_Heavy_FDT50CR-S5_1

COMFORTABLE FUNTIONS

Mitsubishi_Heavy_FDT50CR-S5_5

Fuzzy auto mode
Automatically, the unit determines its operating mode and adjusts the inverter frequency..
Automatic Operation
The air conditioner automatically selects from among heating, cooling and dry operations.

COMFORTABLE AIR FLOW FUNCTIONS

Mitsubishi_Heavy_FDT50CR-S5_6

Auto flap mode
Whatever the operating mode is the unit automatically selects the optimal angle.
Memory flap
While the flap is swinging it can be stopped at any angle desired. The flap returns to  the position that it was in when operation last stopped.
Up/Down flap swing
The UP/DOWN flap can be adjust to the preferred operations angle, ranging from horizontal to perpendicular.

Maintenance & Prevention Funtions

Mitsubishi_Heavy_FDT50CR-S5_7

Microcomputer- Operated Defrosting
This mode automatically eliminates frost and helps minimize excessive operation in other modes.
Self-Diagnostic Funtion
In the case that the air conditioner malfunctions an internal microcomuter automatically runs a self-diagnosis.

CONVENIENCE & ECONOMY FUNCTIONS

Mitsubishi_Heavy_FDT50CR-S5_8

Dry operation
The unit dehumidifies the room by intermittent cooling operation.
Sleep Mode
The room temperature is automatically controlled during the set sleep mode period, ensuring that room temperature will not get too cold or too hot
Off Timer
The unit stops automatically at the set time.
On Timer
This facility enables the operation to start a littel earlier, so that the room approaches optimum temperaure at ON time when the operation is started by ON-TIMER.
Thus it will try to e at the temperature you want.
24-hour On/Off programmanle timer
by combining a start timer with a stop timer, you can register two timer operationsa day. Once set, timers will faithfully start or stop the system at a specified time of the day repeatedly.

OTHERS

Mitsubishi_Heavy_FDT50CR-S5_9

Back-up Switch
On the main unit, there is a backup on/off switch, which is useful when you can't use remote control or batteries are
Auto Restart Funtion
Power blackout auto restart function is a function that records, the operational status of the air-conditioner immediately prior to it being switched off by a power cut and the automatically resumes operations at that point after the power has been restored.

ITEMMODEL
Indoor unitFDT50CR-S5FDT71CR-S5FDT100CR-S5FDT125CR-S5
Outdoor unitFDC50RC-S5FDC71RC-S5FDC100RC-S5FDC125CR-S5
Power source1 Pha, 220/230V, 50Hz3 Pha, 380-415V, 50Hz
CapacitykW57.11012.5
BTU/h17,06024,25534,12042,650
Power consumption W1,6132,2902,9414,464
COP W/W3.13.13.42,80
Exterior dimensions (H x W x D)IndoorkgUnit: 246x840x840/ Panel: 35x950x950
Outdoorkg640x850(+65)x290845x970x370
netweightIndoorm³/min27.529.532.532.5
Outdoorm³/min40477887
RefrigerantR410AR410AR410AR410A
Refrigerant pipingLiquid/Gasmmø 6.35/15.88ø 6.35/15.88ø 9.52/15.88ø 9.52/15.88
PanelT-PSN-3BW-E(Wireless)/ T-PSA-3BW-E
Connecting wiring1.5 mm² x 4 Scores ( Including earth cable)
Connecting methodTerminal block (Screw fixing type)
Controll systemWireless( Standard)Standard ( include T-PSN-3BW-E)
Wire (option)RC-EX1A, RC-E5,RCH-E3 (Option)