Precise Temperature Control
INVERTER prevents wasteful energy consumption by varying the compressor rotation speed to maintain the set temperature.
CONSTANT COMFORT
Precise temperature control with a wide power output range enables an INVERTER air conditioner to meet different room occupancy levels – thus ensuring constant comfort.
How nanoe-G works:
1.REMOVES AIRBORNE PARTICLES (Up to 99%*¹*²)
Removes airborne particles, even down to PM2.5*1. These particles*2 include bacteria, viruses and mould.
2. DEACTIVATES ADHESIVE PARTICLES & DEODORISES ADHESIVE ODOURS (Up to 99%*³)
Deactivates adhesive micro-organisms and deodorises adhesive odours. Inhibits mould growth that settles on surfaces around you.
3. IN-FILTER DEACTIVATION (Up to 99%*⁴)
Deactivates bacteria and viruses trapped in the filter.
AIRBORNE
*¹ PM2.5 Removal was certified by FCG Research Institute, Inc
• Test Report no. : 25034
PM2.5 : Cigarette Smoke (as PM2.5)
Effectiveness is measured on 0.3µm-2.5µm. (Specific size only)
This removal effect is not proven for all the airborne toxic substances.
*² Airborne Removal was certified by Kitasato Research Center for Environmental Science
• KRCES-Bio. Test Report no. : 23_0182
Bacteria : Staphylococcus aureus (NBRC 12732)
• KRCES-Env. Test Report no. : 22_0008
Virus : Escherichia coli phage (øX-174 ATCC 13706-B1)
: Influenza (H1N1) 2009 Virus
• KRCES-Env. Test Report no. : 23_0140
Mould : Penicillium pinophilum (NBRC 6345)
ADHESIVE
*³ Adhesive Deactivation was certified by Japan Food Research Laboratories
• Test Report number : 11047933001-02
Bacteria : Staphylococcus aureus (NBRC 12732)
• Test Report number : 11073649001-02
Virus : Bacteriophage (Phi X 174 NBRC 103405)
• Test Report number : 11047937001-02
Mould : Cladosporium cladosporioides (NBRC 6348)
ADHESIVE ODOURS
Adhesive odour deodorisation was certified by OMI ODOR-AIR SERVICE Co. Ltd.
• Test Report No. 13-1204
IN-FILTER DEACTIVATION
*⁴ In-Filter Deactivation was certified by Japan Food Research Laboratories
• Test Report number : 12037932001
Bacteria : Staphylococcus aureus (NBRC 12732)
• Test Report number : 12014705001
Virus : Escherichia coli phage (øX-174 ATCC 13706-B1)
In-Filter Deactivation was certified by Kitasato Research Center for Environmental Science
• Test Report number : KRCES-Virus Test Report No. 24_0013
Virus : Influenza (H1N1) 2009 Virus
All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.
ALL SPEC
MODEL | (50Hz) | Indoor | CS-PU9TKH-8 |
Outdoor | CU-PU9TKH-8 | ||
Cooling Capacity | (min-max) | kW | 2.55 (0.84-2.280) |
(min-max) | Btu/h | 8,530 (2,860-9,550) | |
CSPF | 4.60 | ||
Electrical Data | Voltage | V | 220 |
Current | A | 3.7 | |
Power Input (mix-max) | W | 750 (225-880) | |
Moisture Removal | L/h | 1.5 | |
(Pt/h) | 3.2 | ||
Air Circulation | Indoor | m³/min (ft³/min) | 10.1 (355) |
Outdoor | m³/min (ft³/min) | 26.7 (940) | |
Noise Level | Indoor (H / L / Q-Lo) | dB (A) | 36/26/23 |
Outdoor (H / L) | dB (A) | 47 | |
Dimensions | Height | mm | 290 (511) |
inch | 11-7/16 (20-1/8) | ||
Width | mm | 870 (650) | |
inch | 34-9/32 (25-19/32) | ||
Depth | mm | 214 (230) | |
inch | 8-7/16 (9-1/16) | ||
Net Weight | Indoor | kg (lb) | 9 (20) |
Outdoor | kg (lb) | 20 (44) | |
Refrigerant Pipe Diameter | Liquid Side | mm | Ø 6.35 |
inch | 1/4 | ||
Gas Side | mm | Ø 9.52 | |
inch | 3/8 | ||
Pipe Extension | Chargeless Pipe Length | m | 7.5 |
Maximum Pipe Length | m | 20 | |
Maximum Elevation Length | m | 15 | |
Additional Refrigerant Gas* | g/m | 10 | |
Power Supply | Indoor |