Inverter
Outdoor Unit AC Multi Daikin Inverter 3MKS50ESG (2.0Hp)
Outdoor Unit AC Multi Daikin Inverter 3MKS50ESG (2.0Hp)
Outdoor Unit AC Multi Daikin Inverter 3MKS50ESG (2.0Hp)

Outdoor Unit AC Multi Daikin Inverter 3MKS50ESG (2.0Hp)

23,500,000
4 công suất làm lạnh. Bạn đang chọn 2.0 Hp
Phí vật tư có thể phát sinh: 825,000đ. Xem chi tiết vật tư.

Email: kinhdoanh@sieuthimaylanh.com
(Open 08. am-17.pm everyday)
Warranty
02 years for components
05 years for compressor
Capacity
Air Conditioner 2.0 HP
Type
Inverter Air Conditioner
Refrigerant
Gas R410A
Specifications
Made in:Brand of Japanese, Made in Thailand
Refrigerant:R410A
Type:Inverter AC - Cooling Only
Cooling Capacity:2.0 Hp
Use For Room:A 2.0 hp outdoor unit, maximum combined with 3 indoor units ( please contact the consultant for further information about the combination of the indoor units and the coefficient of the machine.
Power Input (Ph/V/Hz):1 phase, 220 - 240V, 50Hz
Power consumption (kW):5,0 Kw
Energy Efficiency Level:5 star
Dimensions (H x W x D):735 x 826 x 300 (mm)
Weigh:49 kg
Description

SUPER MULTI NX

The Daikin SUPER MULTI NX lets you build a highly efficient multi room air conditioning system by connecting up to five indoor units to a single outdoor unit.

Air condition your entire home with a single outdoor unit

  • Intelligent technology
  • Ideal environment
  • Interior and exterior flexibility
  • Individual control

Features

Space Saving

  • 1 single outdoor unit can connect to up to 5 indoor units allowing you to make more efficient use of available space in the installation location, such as a balcony.
  • Needs just one compact outdoor unit - keep your home exterior beautiful

spacesaving

High energy saving and quiet operation

  • Daikin energy-saving technologies
    Swing compressor
    Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
    PAM control
    Pulse Amplitude Modulation (PAM) control reduces energy loss by controlling the  amount of switching on/off of the converter.
    Reluctance DC motor
    Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor.
    *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
    *2. The torque created by the change in power between the iron and magnet parts.
  • High COP products
     CoolingHeating
    5MKS100LSG3.69-
    5MXS100LVMA3.654.58

With the combination of:
Multi_Daikin_6
We have created:

Multi_Daikin_8
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory

  • Quiet operation
    A quiet indoor unit is important to your personal comfort.
    Indoor unit operation sound can be up to 22 dB(A) for FTKS/XS model during cooling operation.
    A quiet outdoor unit is essential to your comfort and brings peace to your neighbourhood.
    Outdoor unit: during Outdoor Unit Quiet Operation of cooling operation

          2MKS40: 43 dB (A) 
          2MXS50: 45 dB (A)

quiet_operation

Long piping length for installation flexibility

The ample maximum piping length of 80 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space

Model NameCooling only2MKS403MKS503MKS714MKS805MKS100
Heat pump-3MXS523MXS684MXS805MXS100
Max. Piping lengthTotal30 m50 m60 m70 m80 m
For 1 room20 m25 m30 m

Wide Variety of Indoor Unit

Stylish indoor units for elegant interiors

Multi_Daikin_4
Wall-mounted type
The stylish flat panel design provides an excellent match for interiors.
Multi_Daikin_3
Slim duct-connected type
Bringing hotel style right here in your living room
Multi_Daikin_2_1
Compact Multi Flow Ceiling-Mounted Cassette Type 
Suitable for large space (Living room and dining room in the same area)

Smart control

  • Convenient remote controllers
    A variety of convenient controller systems permit individual control of settings such as temperature, airflow volume, and operation duration.

remote

  • Preferential air conditioning
    (Initial setting required during installation)
    Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners. 
    After a priority room is selected, it receives preferential air-conditioning plus priority control over the 3 functions:
     .  Inverter Powerful Operation
     .  Operation mode (for heatpump only)
     .  Outdoor Unit Quiet Operation
    * Function is not available for 2MKS40E

Multi_Daikin_1_1

Connectable at up to 200% of the outdoor unit capacity class

If all indoor units will not be operated simultaneously, for example, during daytime use of the living room unit or nighttime use of the three bedroom units, the sum of the capacity classes of all indoor units that can be connected is up to 200% of the outdoor unit capacity class

Notes:
1. When an indoor unit is turned on, if the sum of the capacity classes of all indoor units exceeds the limit for simultaneous operation, the unit waits on standby.
2. Even an indoor unit that was initially set as prioritised under Priority-Room Setting waits on standby under the above condition 1.
3. When an indoor unit is turned off, the sum of the capacity classes of all indoor units is within the limit for simultaneous operation, the unit waiting on standby starts automatically.

   2MKS40FV1B3MKS50ESG3MKS71ESG4MKS80ESG5MKS100LSG
 Outdoor unit capacity class  (kW)4.05.07.18.010.0
 Limit of the sum of capacity
classes of all indoor units
 Connectable at 200%  (kW)14.216.020.0
 Simultaneous operation   (kW)6.09.513.515.615.6

* Indoor units can be connected at up to 200% of outdoor units capacity class. All indoor units cannot be operated simultaneously

outdoor-img

Outdoor Unit

A compact and quiet outdoor unit is essential for a less obtrusive exterior look and for your comfort and peace in your neighborhood.

Multi_Daikin_2

Notes:
1. Data is based on the following conditions: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB.
2. The total capacity of connected indoor units to the 3MKS50E is up to 9.5 kW, and the 3MKS71E is up to 13.5 kW,
 and the 4MKS80E is up to 15.6 kW.

Multi_Daikin

Notes:
*1 Rated sound level/sound level when Indoor Unit Quiet Operation and Outdoor Unit Quiet Operation are both selected for all indoor units in operation.
*2 The measurement in parentheses indicates the additional size of the shut-off valve cover.
*3 Additional charging of 20 g/m is required for the 2MKS40FV1B when piping length is 20 m or more.
*4 Additional charging of 20 g/m is required for the 5MKS100LSG when piping length is 40 m or more.

0