Swing compressor
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
PAM control
Pulse Amplitude Modulation (PAM) control reduces energy loss by controlling the amount of switching on/off of the converter.
Reluctance DC motor
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2. The torque created by the change in power between the iron and magnet parts. High COP products
With the combination of:
We have created:
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory
- Quiet operation
A quiet indoor unit is important to your personal comfort.
Indoor unit operation sound can be up to 22 dB(A) for FTKS/XS model during cooling operation.
A quiet outdoor unit is essential to your comfort and brings peace to your neighbourhood.
Outdoor unit: during Outdoor Unit Quiet Operation of cooling operation
2MKS40: 43 dB (A)
2MXS50: 45 dB (A)
Long piping length for installation flexibility
The ample maximum piping length of 80 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space
Wide Variety of Indoor Unit
Stylish indoor units for elegant interiors
Wall-mounted type
The stylish flat panel design provides an excellent match for interiors.
Slim duct-connected type
Bringing hotel style right here in your living room
Compact Multi Flow Ceiling-Mounted Cassette Type
Suitable for large space (Living room and dining room in the same area)
Smart control
- Convenient remote controllers
A variety of convenient controller systems permit individual control of settings such as temperature, airflow volume, and operation duration.
- Preferential air conditioning
(Initial setting required during installation)
Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners.
After a priority room is selected, it receives preferential air-conditioning plus priority control over the 3 functions:
. Inverter Powerful Operation
. Operation mode (for heatpump only)
. Outdoor Unit Quiet Operation
* Function is not available for 2MKS40E
Connectable at up to 200% of the outdoor unit capacity class
If all indoor units will not be operated simultaneously, for example, during daytime use of the living room unit or nighttime use of the three bedroom units, the sum of the capacity classes of all indoor units that can be connected is up to 200% of the outdoor unit capacity class
Notes:
1. When an indoor unit is turned on, if the sum of the capacity classes of all indoor units exceeds the limit for simultaneous operation, the unit waits on standby.
2. Even an indoor unit that was initially set as prioritised under Priority-Room Setting waits on standby under the above condition 1.
3. When an indoor unit is turned off, the sum of the capacity classes of all indoor units is within the limit for simultaneous operation, the unit waiting on standby starts automatically.
* Indoor units can be connected at up to 200% of outdoor units capacity class. All indoor units cannot be operated simultaneously
Indoor Unit
Slim and compact design
Models in the FDKS-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings.
Quiet operation
Quiet operation sound level of only 29 dB (A) is achieved for 2.5 and 3.5 kW class models during
Indoor Unit Quiet Operation.
Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.
* Home Leave Operation can be selected for any temperature from 18 to 32˚C for cooling operation and 10 to 30˚C for heating operation.
* Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home.
Notes:
1. To prevent an increase in operation noise, avoid installing the air suction grille directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Duct-connected types do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.
Note:
* The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for FDKS-EA and 40 Pa
for FDKS-C. Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for FDKS-C.
Review of Indoor Unit Ceiling Duct Multi Daikin FDKS50CVMB (2.0Hp) Inverter
Best selling products
1.0 HP Inverter
- 7,050,000₫
-
11,220,000₫ (-37%)
Energy Star
3.0 HP
- 33,200,000₫
-
39,114,000₫ (-15%)
Energy Star
2.0 HP Inverter
- 19,500,000₫
-
25,000,000₫ (-22%)
Energy Star
1.0 HP Inverter
- 8,300,000₫
-
10,690,000₫ (-22%)
1.0 HP Inverter
- 8,300,000₫
-
10,990,000₫ (-24%)
Energy Star
Viewd products
3.5 HP
- 33,200,000₫
-
38,609,000₫ (-14%)
1.5 HP
- 16,300,000₫
-
18,869,000₫ (-14%)
2.0 HP
- 20,500,000₫
-
23,795,000₫ (-14%)
3.5 HP
- 34,450,000₫
-
40,547,000₫ (-15%)
Energy Star